The FTIR has a detection limit of ~5%. Substances below this level may not appear in results — even if they are toxic or affect the potency of your sample.
Any percentage estimates are approximate. They may not reflect actual potency, and similar-looking samples can yield different results.
A sample may not reflect the full composition of a drug. For example, testing a portion of a pill may not represent the rest of the pill, or other pills from the same batch. Cross-contamination between samples stored together can also affect results.
When we detect only one substance, we don’t provide a percentage because other ingredients might still be present below the 5% detection limit.
Treat any percentage result as a rough guideline, not a precise measurement.
Tests highlighted in red indicate particularly dangerous or unexpected results. Flagged samples can alslo be viewed on our Alerts page.
The uncertain match in this sample shares similarities with THC but the signal was too heavy on the carrier oil to confirm that it is THC in this sample.
This sample has similarities to 3-Chlorocathinone and 3-Chloromethcathinone, but also has structures similar to various methamphetamines.
Vancouver, BC
01/28/2024
Category: Stimulant White Powder Code: roadrunner
Methamphetamine
Methamphetamine
Fentanyl: Negative Benzodiazepine: Negative
Vancouver, BC
01/28/2024
Category: Other Brown Powder
Mitragynine
Uncertain Carbohydrate
N/A
Uncertain Match
N/A
Uncertain Oil
N/A
Fentanyl: Negative
This result is typical of ground plant sources of mitragynine, as the active ingredients are usually present in amounts too small to detect by FTIR.
Vancouver, BC
01/28/2024
Category: Stimulant White Powder Code: super
4-MMC
4-MMC
Fentanyl: Negative
Vancouver, BC
01/28/2024
Category: Stimulant White Powder Code: A2
Cocaine
Cocaine
Fentanyl: Negative
Anonymous, BC
01/28/2024
Category: Opioid Light Green Chunk
Hydromorphone
Microcrystalline Cellulose
N/A
Uncertain Carbohydrate
N/A
Uncertain Oil
N/A
Uncertain Match
N/A
Fentanyl: Negative Benzodiazepine: Negative
It is possible that this sample contains hydromorphone in amounts below or close to the detection threshold of the FTIR. Identifying hydromorphone in this sample was difficult due to the amount of uncertain filler components present.
Category: Depressant White Pressed Pill Code: caliban
Flualprazolam
Microcrystalline Cellulose
90-95%
Uncertain Match
5-10%
Fentanyl: Negative Benzodiazepine: Positive
Imprint: XANAX / 2
Anonymous, BC
01/28/2024
Category: Stimulant White Granules Code: Redlime
Cocaine
Cocaine
Fentanyl: Negative
Vancouver, BC
01/28/2024
Category: Opioid Yellow Pebble
Fentanyl
Fentanyl
Fentanyl: Positive Benzodiazepine: Negative
Vancouver, BC
01/28/2024
Category: Opioid Red Paste Code: redlime wobbles
Down
Fentanyl or analog
30-35%
Desalkylgidazepam
25-30%
Caffeine
20-25%
Uncertain Match
10-15%
Fentanyl: Positive Benzodiazepine: Positive
Desalkylgidazepam is a novel benzodiazepine drug that was introduced into clinical practice in Russia in 1997. It is an active metabolite of the atypical benzodiazepine gidazepam. It acts as an anxiolytic, and is structurally related to the drug bromazepam.