The FTIR has a detection limit of approximately 5%. Substances below this level may not appear in results — even if they are toxic or affect the potency of your sample.
When possible, we may provide a percentage estimate based on what the FTIR detects. These numbers are generated by software and reflect only the visible components — not the full composition of the sample. The FTIR cannot isolate individual substances in complex mixtures, so any percentage estimates are approximate. They may not reflect actual potency, and similar-looking samples can yield different results – therefore we do not provide purity testing. Any percentages we offer are estimates based on the visible ingredients identified through FTIR spectroscopy. Since this method does not account for the entire sample, undetected ingredients below the detection threshold may influence the composition. The percentages are intended only as a general indication of how the identified ingredients are distributed within the sample. Due to this, any percentages provided cannot be used to calculate milligram quantities within a sample. Our results should not be used to determine exact dosages.
Additionally, a sample may not reflect the full composition of a drug. For example, testing part of a pill may not represent the rest. Cross-contamination between samples stored together can also affect results.
When we detect only one substance, we don’t provide a percentage because other ingredients might still be present below the 5% detection limit.
Treat any percentage result as a rough guideline, not a precise measurement.
Tests highlighted in red indicate particularly dangerous or unexpected results. Flagged samples can alslo be viewed on our Alerts page.
We also use test strips to detect the presence of fentanyl, benzodiazapenes, and lysergamide (LSD).
The results provided are strictly for personal use and educational purposes. They must not be published, distributed, or shared publicly in any form. Unauthorized sharing, reproduction, or publication of these results is strictly prohibited and may result in disciplinary action.
If you find our results shared elsewhere, please be aware that such use is unauthorized and we do not condone it. Images or representations of our results can be easily replicated or altered online, potentially containing misleading or false information. We strongly recommend testing your own samples to ensure accuracy and reliability.
Cross contamination is suspected for the positive results with the fentanyl test strip. After reaching out to this person they came back and we were able to test this sample again. Cross contamination was the cause for the positive result.
Vancouver, BC
12/15/2022
Category: Unknown Light Brown Granules
Unknown
Caffeine
50-55%
Erythritol
25-30%
Fentanyl
20-25%
Fentanyl: Positive Benzodiazepine: Negative
Vancouver, BC
12/15/2022
Category: Opioid White Pressed Pill
Oxycodone
Dicalcium Phosphate
50-55%
Uncertain Mineral
15-20%
Uncertain Carbohydrate
10-15%
Oxycodone
5-10%
Uncertain Match
5-10%
Fentanyl: Negative Benzodiazepine: Negative
Imprint: SS / 20
Vancouver, BC
12/15/2022
Category: Opioid Purple Granules
Fentanyl
Caffeine
35-40%
Erythritol
20-25%
Fentanyl or analog
15-20%
Sucrose
15-20%
Uncertain Match
5-10%
Fentanyl: Positive Benzodiazepine: Positive
Timmins, ON
12/15/2022
Category: Psychedelic Purple Crystal
MDMA
MDMA
Fentanyl: Negative
Vancouver, BC
12/15/2022
Category: Psychedelic Purple Crystal
MDMA
MDMA
Fentanyl: Negative
Vancouver, BC
12/15/2022
Category: Psychedelic White Crystal Code: 7777
Ketamine
Ketamine
Fentanyl: Negative
Vancouver, BC
12/15/2022
Category: Psychedelic Blue Granules Code: 7777
MDMA
MDMA
50-55%
Microcrystalline Cellulose
40-45%
Uncertain Oil
5-10%
Fentanyl: Negative
Vancouver, BC
12/15/2022
Category: Unknown Light Yellow Powder
Unknown
Fentanyl
90-95%
Uncertain Match
5-10%
Fentanyl: Positive Benzodiazepine: Negative
Vancouver, BC
12/15/2022
Category: Unknown Light Yellow Powder
Unknown
No Library Match
Fentanyl: Negative Benzodiazepine: Positive
Vancouver, BC
12/15/2022
Category: Psychedelic Dark Yellow Pressed Pill
2C-B HCl
Microcrystalline Cellulose
50-55%
2C-B HCl
45-50%
Fentanyl: Negative
Imprint: Superman Logo
Vancouver, BC
12/15/2022
Category: Psychedelic Light Blue Pressed Pill
MDMA
Microcrystalline Cellulose
50-55%
MDMA
45-50%
Fentanyl: Negative
Vancouver, BC
12/15/2022
Category: Opioid Colourless Flake
Fentanyl
1-Boc-4-(4F-Phenylamino)-Piperidine
Fentanyl: Negative Benzodiazepine: Negative
Vancouver, BC
12/15/2022
Category: Depressant Light Green Pressed Pill
Bromazolam
Microcrystalline Cellulose
75-80%
Bromazolam
5-10%
Uncertain Oil
5-10%
Uncertain Match
5-10%
Fentanyl: Negative Benzodiazepine: Positive
Imprint: XANAX / 2
Vancouver, BC
12/15/2022
Category: Opioid Light Grey Granules
Fentanyl
1-Boc-4-(4F-Phenylamino)-Piperidine
Fentanyl: Negative Benzodiazepine: Negative
Vancouver, BC
12/15/2022
Category: Opioid Grey Granules
Fentanyl
1-Boc-4-(4F-Phenylamino)-Piperidine
Fentanyl: Negative Benzodiazepine: Negative
Vancouver, BC
12/15/2022
Category: Psychedelic Colourless Crystal
Ketamine
Ketamine
90-95%
Dimethyl Sulfone
5-10%
Fentanyl: Negative
Vancouver, BC
12/15/2022
Category: Stimulant Colourless Crystal
Methamphetamine
No FTIR
Fentanyl: Negative Benzodiazepine: Negative
This sample did not produce a spectrum when placed on the spectrometer for analysis.