The FTIR has a detection limit of approximately 5%. Substances below this level may not appear in results — even if they are toxic or affect the potency of your sample.
When possible, we may provide a percentage estimate based on what the FTIR detects. These numbers are generated by software and reflect only the visible components — not the full composition of the sample. The FTIR cannot isolate individual substances in complex mixtures, so any percentage estimates are approximate. They may not reflect actual potency, and similar-looking samples can yield different results – therefore we do not provide purity testing. Any percentages we offer are estimates based on the visible ingredients identified through FTIR spectroscopy. Since this method does not account for the entire sample, undetected ingredients below the detection threshold may influence the composition. The percentages are intended only as a general indication of how the identified ingredients are distributed within the sample. Due to this, any percentages provided cannot be used to calculate milligram quantities within a sample. Our results should not be used to determine exact dosages.
Additionally, a sample may not reflect the full composition of a drug. For example, testing part of a pill may not represent the rest. Cross-contamination between samples stored together can also affect results.
When we detect only one substance, we don’t provide a percentage because other ingredients might still be present below the 5% detection limit.
Treat any percentage result as a rough guideline, not a precise measurement.
Tests highlighted in red indicate particularly dangerous or unexpected results. Flagged samples can alslo be viewed on our Alerts page.
We also use test strips to detect the presence of fentanyl, benzodiazapenes, and lysergamide (LSD).
The results provided are strictly for personal use and educational purposes. They must not be published, distributed, or shared publicly in any form. Unauthorized sharing, reproduction, or publication of these results is strictly prohibited and may result in disciplinary action.
If you find our results shared elsewhere, please be aware that such use is unauthorized and we do not condone it. Images or representations of our results can be easily replicated or altered online, potentially containing misleading or false information. We strongly recommend testing your own samples to ensure accuracy and reliability.
The uncertain match in this sample appears to be a fentanyl precursor or analog.
Vancouver, BC
03/27/2022
Category: Stimulant White Flake
Cocaine
Cocaine
85-90%
Uncertain Match
10-15%
Fentanyl: Negative Benzodiazepine: Negative
The uncertain match in this sample appears to be a form of glucosamine but it cannot be confirmed.
Vancouver, BC
03/27/2022
Category: Psychedelic White Blotter
LSD
No FTIR
Fentanyl: Negative Lysergamide: Positive
Vancouver, BC
03/27/2022
Category: Opioid Light Grey Powder
Heroin
Heroin
60-65%
Caffeine
35-40%
Fentanyl: Negative Benzodiazepine: Negative
Vancouver, BC
03/27/2022
Category: Stimulant White Powder
Cocaine
Cocaine
Fentanyl: Negative
Vancouver, BC
03/27/2022
Category: Psychedelic Purple Crystal Code: Pacman
MDMA
MDMA
Fentanyl: Negative
Vancouver, BC
03/27/2022
Category: Stimulant White Powder
Cocaine
Caffeine
50-55%
Mannitol
20-25%
Fentanyl
10-15%
Uncertain Match
5-10%
Fentanyl: Positive Benzodiazepine: Negative
this sample was brought in with another one and they were both alike. The uncertain match is suspected to be etizolam or a similar substance but cannot be confirmed.
Vancouver, BC
03/27/2022
Category: Psychedelic Light Brown Pebble
MDMA
MDMA
Fentanyl: Negative
Vancouver, BC
03/27/2022
Category: Stimulant White Granules
Cocaine
Caffeine
45-50%
Mannitol
40-45%
Uncertain Match
5-10%
Fentanyl: Positive Benzodiazepine: Negative
The uncertain match in this sample may be Etizolam or a similar substance but cannot be confirmed.
Vancouver, BC
03/27/2022
Category: Unknown White Powder
Unknown
Cocaine
Fentanyl: Negative Benzodiazepine: Negative
Vancouver, BC
03/27/2022
Category: Unknown White Chunk
Unknown
Cocaine Base
Fentanyl: Negative Benzodiazepine: Negative
Vancouver, BC
03/27/2022
Category: Unknown Light Yellow Powder
Unknown
Fentanyl
85-90%
Uncertain Match
10-15%
Fentanyl: Positive Benzodiazepine: Negative
Vancouver, BC
03/27/2022
Category: Unknown Dark Yellow Chunk Code: craigslist
Unknown
Fentanyl
85-90%
Uncertain Match
10-15%
Fentanyl: Positive
The uncertain match in this sample is likely a fentanyl analogue and/or fentanyl precursors