The FTIR has a detection limit of approximately 5%. Substances below this level may not appear in results — even if they are toxic or affect the potency of your sample.
When possible, we may provide a percentage estimate based on what the FTIR detects. These numbers are generated by software and reflect only the visible components — not the full composition of the sample. The FTIR cannot isolate individual substances in complex mixtures, so any percentage estimates are approximate. They may not reflect actual potency, and similar-looking samples can yield different results – therefore our results are not suitable for purity testing.
Undetected ingredients below the detection threshold may influence the composition. Any percentages listed intended only as a general indication of how the identified ingredients are distributed within the sample. Due to this, our results should not be used to determine exact dosages.
Additionally, a sample may not reflect the full composition of a drug. For example, testing a portion of a pill may not represent the rest of the pill, or other pills from the same batch. Cross-contamination between samples stored together can also affect results.
When we detect only one substance, we don’t provide a percentage because other ingredients might still be present below the 5% detection limit.
Treat any percentage result as a rough guideline, not a precise measurement.
Tests highlighted in red indicate particularly dangerous or unexpected results. Flagged samples can alslo be viewed on our Alerts page.
We also use test strips to detect the presence of fentanyl, benzodiazapenes, and lysergamide (LSD).
Despropionyl para-fluorofentanyl is a precursor chemical in the manufacturing of para-fluorofentanyl. It does not trigger fentanyl test strips & research is unclear if it has any opioid like effects.
Ketamine freebase is the base form of ketamine. Since ketamine is often sold in salt crystal form, it cannot be smoked until it is converted into its base form by combining with a basic substance such as sodium bicarbonate. Ketamine freebase is not water soluble and therefore unsafe to inject.
Vancouver, BC
07/18/2024
Category: Opioid Brown Pebble
Down
Caffeine
40-45%
Para-Fluorofentanyl
30-35%
Uncertain Match
20-25%
Fentanyl: Positive Benzodiazepine: Negative
Vancouver, BC
07/18/2024
Category: Opioid Purple Pebble
Down
Caffeine
50-55%
Uncertain Match
30-35%
Para-Fluorofentanyl
10-15%
Fentanyl: Positive Benzodiazepine: Positive
Vancouver, BC
07/18/2024
Category: Opioid Light Brown Pebble
Down
Caffeine
35-40%
Erythritol
30-35%
Para-Fluorofentanyl Base
15-20%
Uncertain Match
10-15%
Fentanyl: Positive Benzodiazepine: Negative
The uncertain match in this sample resembles some known fentanyl precursors but could not be confirmed.
Vancouver, BC
07/18/2024
Category: Psychedelic White Crystal Code: missmuscle
MDMA
MDMA
Fentanyl: Negative
Vancouver, BC
07/18/2024
Category: Psychedelic Colourless Crystal
Ketamine
Methamphetamine
Fentanyl: Negative
Sample had been consumed and was reported to have caused panic attacks.