The FTIR has a detection limit of approximately 5%. Substances below this level may not appear in results — even if they are toxic or affect the potency of your sample.
When possible, we may provide a percentage estimate based on what the FTIR detects. These numbers are generated by software and reflect only the visible components — not the full composition of the sample. The FTIR cannot isolate individual substances in complex mixtures, so any percentage estimates are approximate. They may not reflect actual potency, and similar-looking samples can yield different results – therefore our results are not suitable for purity testing.
Undetected ingredients below the detection threshold may influence the composition. Any percentages listed intended only as a general indication of how the identified ingredients are distributed within the sample. Due to this, our results should not be used to determine exact dosages.
Additionally, a sample may not reflect the full composition of a drug. For example, testing a portion of a pill may not represent the rest of the pill, or other pills from the same batch. Cross-contamination between samples stored together can also affect results.
When we detect only one substance, we don’t provide a percentage because other ingredients might still be present below the 5% detection limit.
Treat any percentage result as a rough guideline, not a precise measurement.
Tests highlighted in red indicate particularly dangerous or unexpected results. Flagged samples can alslo be viewed on our Alerts page.
We also use test strips to detect the presence of fentanyl, benzodiazapenes, and lysergamide (LSD).
Category: Stimulant White Crystal Code: bongblaster2
Methamphetamine
Methamphetamine
85-90%
Dimethyl Sulfone
10-15%
Fentanyl: Negative
Vancouver, BC
07/17/2024
Category: Opioid Yellow Pebble
Fentanyl
Para-Fluorofentanyl
90-95%
Uncertain Match
5-10%
Fentanyl: Positive Benzodiazepine: Negative
Vancouver, BC
07/17/2024
Category: Depressant White Chunk Code: knife
Alprazolam
Microcrystalline Cellulose
65-70%
Polyvinylpyrrolidone
15-20%
Uncertain Oil
10-15%
Fentanyl: Negative Benzodiazepine: Negative
This sample tested negative for benzodiazepines by test strip. There may be an active ingredient below our FTIR's 5% detection limit, such as etizolam that does not trigger the benzodiazepine test strips, but we cannot confirm.
Vancouver, BC
07/17/2024
Category: Opioid Brown Granules
Fentanyl
Fentanyl
80-85%
Uncertain Match
15-20%
Fentanyl: Positive Benzodiazepine: Negative
The uncertain match in this sample is likely leftover precursors and/or solvents but could not be confirmed.
Vancouver, BC
07/17/2024
Category: Unknown Light Brown Powder
Unknown
Bromazolam
Fentanyl: Negative Benzodiazepine: Positive
Vancouver, BC
07/17/2024
Category: Unknown Brown Pebble
Unknown
Para-Fluorofentanyl
50-55%
Fentanyl
45-50%
Fentanyl: Positive Benzodiazepine: Negative
Vancouver, BC
07/17/2024
Category: Psychedelic White Powder Code: Arch-XYZ-C
2C-B HCl
2C-Family
Fentanyl: Negative
Anonymous, BC
07/17/2024
Category: Psychedelic White Powder Code: Arch-XYZ-B
2C-B HCl
2C-B HCl
Fentanyl: Negative
Anonymous, BC
07/17/2024
Category: Opioid White Tablet
Acetaminophen and Oxycodone
Acetaminophen
80-85%
Uncertain Carbohydrate
10-15%
Uncertain Oil
5-10%
Fentanyl: Negative Benzodiazepine: Negative
Imprint: TEC
Vancouver, BC
07/17/2024
Category: Psychedelic White Powder Code: Arch-XYZ-A
Uncertain Match means we were unable to identify one or more parts of your substance. This may be because the remaining signal is small, indistinct, or we otherwise cannot match this remaining signal to any substance in our reference libraries.