The FTIR has a detection limit of approximately 5%. Substances below this level may not appear in results — even if they are toxic or affect the potency of your sample.
When possible, we may provide a percentage estimate based on what the FTIR detects. These numbers are generated by software and reflect only the visible components — not the full composition of the sample. The FTIR cannot isolate individual substances in complex mixtures, so any percentage estimates are approximate. They may not reflect actual potency, and similar-looking samples can yield different results – therefore we do not provide purity testing. Any percentages we offer are estimates based on the visible ingredients identified through FTIR spectroscopy. Since this method does not account for the entire sample, undetected ingredients below the detection threshold may influence the composition. The percentages are intended only as a general indication of how the identified ingredients are distributed within the sample. Due to this, any percentages provided cannot be used to calculate milligram quantities within a sample. Our results should not be used to determine exact dosages.
Additionally, a sample may not reflect the full composition of a drug. For example, testing part of a pill may not represent the rest. Cross-contamination between samples stored together can also affect results.
When we detect only one substance, we don’t provide a percentage because other ingredients might still be present below the 5% detection limit.
Treat any percentage result as a rough guideline, not a precise measurement.
Tests highlighted in red indicate particularly dangerous or unexpected results. Flagged samples can alslo be viewed on our Alerts page.
We also use test strips to detect the presence of fentanyl, benzodiazapenes, and lysergamide (LSD).
The results provided are strictly for personal use and educational purposes. They must not be published, distributed, or shared publicly in any form. Unauthorized sharing, reproduction, or publication of these results is strictly prohibited and may result in disciplinary action.
If you find our results shared elsewhere, please be aware that such use is unauthorized and we do not condone it. Images or representations of our results can be easily replicated or altered online, potentially containing misleading or false information. We strongly recommend testing your own samples to ensure accuracy and reliability.
Histidine is an essential amino acid that is used in the biosynthesis of proteins. It has a role as an anticonvulsant, an antioxidant, an antineoplastic agent, a human metabolite, a Daphnia magna metabolite, a mouse metabolite, a neuroprotective agent and a geroprotector. It is a conjugate acid of a carnosinate.
Category: Psychedelic Blue Chunk Code: pinkandblue
MDMA
Caffeine
45-50%
MDMA
25-30%
Uncertain Oil
15-20%
Uncertain Match
5-10%
Fentanyl: Negative
The uncertain match shares similarities with multiple carbohydrates and minerals but could not be confirmed. This is likely another ingredient used as a pill filler.
Vancouver, BC
04/09/2024
Category: Opioid Brown Granules Code: Halls - yellow
Down
Caffeine
45-50%
Erythritol
35-40%
Para-Fluorofentanyl
10-15%
Fentanyl: Positive Benzodiazepine: Negative
Vancouver, BC
04/09/2024
Category: Opioid Blue Chunk
Acetaminophen and Oxycodone
Acetaminophen
40-45%
Mannitol
15-20%
Calcium Stearate
15-20%
Uncertain Carbohydrate
10-15%
Uncertain Match
5-10%
Fentanyl: Positive Benzodiazepine: Negative
The uncertain match in this sample is likely a fentanyl analogue not in our libraries, but can not be confirmed as such.
Anonymous, BC
04/09/2024
Category: Opioid Green Granules Code: Halls - green
Down
Caffeine
35-40%
Fentanyl
30-35%
Erythritol
25-30%
Fentanyl: Positive Benzodiazepine: Negative
Vancouver, BC
04/09/2024
Category: Stimulant White Powder Code: apple
Cocaine
Cocaine
Fentanyl: Negative
Vancouver, BC
04/09/2024
Category: Psychedelic Colourless Crystal
MDMA
MDMA
Fentanyl: Negative
Vancouver, BC
04/09/2024
Category: Unknown Colourless Crystal
Unknown
Methamphetamine
Fentanyl: Negative Benzodiazepine: Negative
Vancouver, BC
04/09/2024
Category: Unknown White Crystal
Unknown
Ketamine
Fentanyl: Negative Benzodiazepine: Negative
Vancouver, BC
04/09/2024
Category: Opioid Yellow Chunk
Fentanyl
Para-Fluorofentanyl
90-95%
Uncertain Match
5-10%
Fentanyl: Positive Benzodiazepine: Negative
The uncertain match in this sample may be a fentanyl analog or precursor not present in our reference libraries
Vancouver, BC
04/09/2024
Category: Opioid Dark Purple Granules Code: 0401004
Down
Erythritol
65-70%
Uncertain Match
15-20%
Fentanyl
10-15%
Fentanyl: Positive Benzodiazepine: Negative
The uncertain match in this sample is likely a mixture of a fentanyl analogue not in our libraries and another carbohydrate; however, this could not be confirmed.
Anonymous, BC
04/09/2024
Category: Psychedelic Grey Crystal
MDMA
MDMA
90-95%
Methamphetamine
5-10%
Fentanyl: Negative
Vancouver, BC
04/09/2024
Category: Psychedelic Purple Crystal
MDMA
MDMA
Fentanyl: Negative
Vancouver, BC
04/09/2024
Category: Opioid Light Brown Powder Code: juice
Down
Bromazolam
40-45%
Caffeine
20-25%
Erythritol
15-20%
Fentanyl or analog
5-10%
Uncertain Oil
5-10%
Fentanyl: Positive Benzodiazepine: Positive
This sample has a much higher benzodiazepine content than other down samples we've seen and may increase the risk of complex overdose that does not respond to naloxone
Vancouver, BC
04/09/2024
Category: Stimulant White Crystal Code: 0401003
Methamphetamine
Methamphetamine
Fentanyl: Negative Benzodiazepine: Negative
Anonymous, BC
04/09/2024
Category: Psychedelic White Crystal
Ketamine
Ketamine
Fentanyl: Negative
Vancouver, BC
04/09/2024
Category: Psychedelic Brown Organic Code: 0401002
Mushroom and Derivatives
No FTIR
Fentanyl: Negative
Our FTIR machine is not designed for testing organic material because they are made of a multitude of compounds and plant material. Through infrared spectrometry, all we see is carbohydrates, sugars and cellulose. Our machine also has a detection threshold of 5% which means any ingredient under 5% we cannot see. Most often the active ingredient of the plant is under that detection threshold.