The FTIR has a detection limit of approximately 5%. Substances below this level may not appear in results — even if they are toxic or affect the potency of your sample.
When possible, we may provide a percentage estimate based on what the FTIR detects. These numbers are generated by software and reflect only the visible components — not the full composition of the sample. The FTIR cannot isolate individual substances in complex mixtures, so any percentage estimates are approximate. They may not reflect actual potency, and similar-looking samples can yield different results – therefore our results are not suitable for purity testing.
Undetected ingredients below the detection threshold may influence the composition. Any percentages listed intended only as a general indication of how the identified ingredients are distributed within the sample. Due to this, our results should not be used to determine exact dosages.
Additionally, a sample may not reflect the full composition of a drug. For example, testing a portion of a pill may not represent the rest of the pill, or other pills from the same batch. Cross-contamination between samples stored together can also affect results.
When we detect only one substance, we don’t provide a percentage because other ingredients might still be present below the 5% detection limit.
Treat any percentage result as a rough guideline, not a precise measurement.
Tests highlighted in red indicate particularly dangerous or unexpected results. Flagged samples can alslo be viewed on our Alerts page.
We also use test strips to detect the presence of fentanyl, benzodiazapenes, and lysergamide (LSD).
Category: Psychedelic White Granules Code: RR-MD/24/01
MDMA
MDMA
Fentanyl: Negative
Anonymous, BC
02/14/2024
Category: Opioid Pink Granules Code: diesel5au
Down
Erythritol
45-50%
Caffeine
25-30%
Xylazine
10-15%
Uncertain Match
10-15%
Fentanyl: Positive Benzodiazepine: Positive
Wainwright, AB
02/14/2024
Category: Psychedelic White Granules Code: TM-2CB/24/01
2C-B HCl
2C-Family
Fentanyl: Negative
Anonymous, BC
02/14/2024
Category: Other White Tablet Code: SomaFeb52024
Carisoprodol
Carisoprodol
Fentanyl: Negative
Anonymous, BC
02/14/2024
Category: Depressant White Tablet Code: Tof1002024
Tofisopam
Lactose
45-50%
Uncertain Match
40-45%
Uncertain Oil
5-10%
Fentanyl: Negative Benzodiazepine: Negative
We do not have tofisopam in our reference libraries. Additionally the results on the benzodiazepine test strip were negative. This may be due to the fact that tofisopam is a 2,3-benzodiazepine drug which is a benzodiazepine derivative & our test strips are manufactured for classical 1,4-benzodiazepines.
Anonymous, BC
02/14/2024
Category: Depressant White Tablet Code: Tof502024
Tofisopam
Lactose
55-60%
Uncertain Match
30-35%
Uncertain Oil
5-10%
Fentanyl: Negative Benzodiazepine: Negative
We do not have tofisopam in our reference libraries. Additionally the results on the benzodiazepine test strip were negative. This may be due to the fact that tofisopam is a 2,3-benzodiazepine drug which is a benzodiazepine derivative & our test strips are manufactured for classical 1,4-benzodiazepines.
Anonymous, BC
02/14/2024
Category: Psychedelic Purple Crystal
MDMA
MDMA
Fentanyl: Negative
Vancouver, BC
02/14/2024
Category: Opioid Light Brown Granules Code: ghostkeeper
Down
Erythritol
35-40%
Caffeine
35-40%
Mannitol
15-20%
Uncertain Match
5-10%
Fentanyl: Positive Benzodiazepine: Negative
Wainwright, AB
02/14/2024
Category: Psychedelic Blue Crystal
MDMA
MDMA
Fentanyl: Negative
Vancouver, BC
02/14/2024
Category: Psychedelic Yellow Blotter
LSD
No FTIR
Fentanyl: Negative Lysergamide: Positive
Vancouver, BC
02/14/2024
Category: Depressant White Tablet
Lorazepam
Lactose
85-90%
Lorazepam
5-10%
Uncertain Oil
5-10%
Fentanyl: Negative Benzodiazepine: Positive
Imprint: APO / 2
Vancouver, BC
02/14/2024
Category: Other White Chunk
Zolpidem
Uncertain Carbohydrate
75-80%
Talc
5-10%
Uncertain Oil
5-10%
Uncertain Match
5-10%
Fentanyl: Negative Benzodiazepine: Negative
The uncertain match in this sample resembles zolpidem, however the reamaining signal is too small/ indistinct to confirm as such.