The FTIR has a detection limit of approximately 5%. Substances below this level may not appear in results — even if they are toxic or affect the potency of your sample.
When possible, we may provide a percentage estimate based on what the FTIR detects. These numbers are generated by software and reflect only the visible components — not the full composition of the sample. The FTIR cannot isolate individual substances in complex mixtures, so any percentage estimates are approximate. They may not reflect actual potency, and similar-looking samples can yield different results – therefore we do not provide purity testing. Any percentages we offer are estimates based on the visible ingredients identified through FTIR spectroscopy. Since this method does not account for the entire sample, undetected ingredients below the detection threshold may influence the composition. The percentages are intended only as a general indication of how the identified ingredients are distributed within the sample. Due to this, any percentages provided cannot be used to calculate milligram quantities within a sample. Our results should not be used to determine exact dosages.
Additionally, a sample may not reflect the full composition of a drug. For example, testing part of a pill may not represent the rest. Cross-contamination between samples stored together can also affect results.
When we detect only one substance, we don’t provide a percentage because other ingredients might still be present below the 5% detection limit.
Treat any percentage result as a rough guideline, not a precise measurement.
Tests highlighted in red indicate particularly dangerous or unexpected results. Flagged samples can alslo be viewed on our Alerts page.
We also use test strips to detect the presence of fentanyl, benzodiazapenes, and lysergamide (LSD).
The results provided are strictly for personal use and educational purposes. They must not be published, distributed, or shared publicly in any form. Unauthorized sharing, reproduction, or publication of these results is strictly prohibited and may result in disciplinary action.
If you find our results shared elsewhere, please be aware that such use is unauthorized and we do not condone it. Images or representations of our results can be easily replicated or altered online, potentially containing misleading or false information. We strongly recommend testing your own samples to ensure accuracy and reliability.
This sample is likely a nitazene not in our libraries, but can not be confirmed as such.Nitazenes are potent synthetic opioids from a drug class known as benzimidazole-opioids. Some nitazenes are estimated to be several times more potent than fentanyl. They were developed 60 years ago as potential pain relief medication, but were never approved for clinical use. They typically appear unexpectedly in drugs expected to contain other more traditional opioids (e.g., fentanyl, oxycodone tablets or “down”), often alongside non-medical benzodiazepines (NMBs).
Vancouver, BC
07/31/2023
Category: Unknown Light Orange Powder Code: poultry B
Unknown
Bromazolam
Fentanyl: Negative Benzodiazepine: Positive
Vancouver, BC
07/31/2023
Category: Depressant White Pressed Pill Code: KP480
While both 4-MMC and dimethylpentylone are in the cathinone class of substances there can still be issues of dose amounts and overall effects that mean they are not interchangable.
Anonymous, BC
07/30/2023
Category: Opioid Light Brown Granules
Down
Para-Fluorofentanyl
55-60%
Uncertain Match
40-45%
Fentanyl: Positive Benzodiazepine: Negative
The uncertain match in this sample is likely a fentanyl analogue not in our libraries, but can not be confirmed.
Vancouver, BC
07/30/2023
Category: Psychedelic White Powder
2C-B HCl
No Library Match
Fentanyl: Negative
This sample appears to be amphetamine-related but does not match clearly with anything in our reference libaries.